beautypg.com

Comtech EF Data SLM-5650A User Manual

Page 385

background image

SLM-5650A Satellite Modem

Revision 8

Appendix C

MN-SLM5650A

C–33

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

ASYNC ESC

Rx Baud Rate

ARB=

1 byte

Command or Query.
Baud Rate, where:

0=110

1=150

2=300

3=600

4=1200

5=2400

6=4800

7=9600

8=19200

9=38400
Example: ARB=0 (sets the ASYNC ESC Rx Baud Rate to 110 Baud)

ARB=

ARB?

ARB*

ARB#

ARB?

ARB=x

(see Description

of Arguments)

ASYNC ESC

Rx Format

ARF=

2 bytes

Command or Query.
Async Format, where:

00=7 Bits, No Parity, 1 Stop Bit

01=7 Bits, Even Parity, 1 Stop Bit

02=7 Bits, Odd Parity, 1 Stop Bit

03=7 Bits, No Parity, 2 Stop Bits

04=7 Bits, Even Parity, 2 Stop Bits

05=7 Bits, Odd Parity, 2 Stop Bits

06=8 Bits, No Parity, 1 Stop Bit

07=8 Bits, Even Parity, 1 Stop Bit

08=8 Bits, Odd Parity, 1 Stop Bit

09=8 Bits, No Parity, 2 Stop Bits

10=8 Bits, Even Parity, 2 Stop Bits

11=8 Bits, Odd Parity, 2 Stop Bits
Example: ARF=0 (sets the ASYNC ESC Rx Format to 7N1)

ARF=

ARF?

ARF*

ARF#

ARF?

ARF=xx

(see Description

of Arguments)

AUPC Log

Sample Interval

ASI=

1 byte

Command or Query.
Used to set the sample interval for the AUPC Logging Function in the form x, where:

x = 0 to 9 in 10 minute steps.

Note: Setting this parameter to 0 disables the logging function.
Example: ASI=3 (sets the logging inverval to 30 minutes)

ASI=

ASI?

ASI*

ASI#

ASI?

ASI=x

(see Description

of Arguments)