beautypg.com

Comtech EF Data SLM-5650A User Manual

Page 379

background image

SLM-5650A Satellite Modem

Revision 8

Appendix C

MN-SLM5650A

C–27

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

BERT Pattern

PAT=

1 byte, value of 0

thru 8

Command or Query.
BERT Pattern, where:

0=2047

1=Mark

2=Space

3=1:1

4=1:2

5=2^15-1

6=2^20-1

7=2^23-1

8=MIL-188

Example: PAT=0 (2047 Pattern)

PAT=

PAT?

PAT*

PAT#

PAT?

PAT=x

(see Description

of Arguments)

Retrieve next 5

unread Stored

Events

N/A

110 bytes

Query only.
Unit returns the oldest 5 Stored Events which have not yet been read over the

remote control.
Reply format: {CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-

body, where Sub-body= Axxxxxxxxddmmyyhhmmss, A being the fault type where:

1=Unit

2=Rx Traffic

3=Tx Traffic

4=Info

xxxxxxxx is the Fault Code number, as in LUF?, TXF?, RXF?, or Info Code,

which is:

00000000=Power Off

00000001=Power On

00000002=Log Cleared

00000004=Global Config Change

00000005=NP Card Watch Dog Timer

00000006=NP Card Boot Timeout

00000007=Transec Card Boot Timeout

If there are less than 5 events to be retrieved, the remaining positions are padded

with zeros.
If there are no new events, the response is RNE*.

N/A

RNE?

RNE={CR}Axxxxx

xxxddmmyyhhmm

ss{CR}Axxxxxxxx

ddmmyyhhmmss{

CR}Axxxxxxxxdd

mmyyhhmmss{CR

}Axxxxxxxxddmm

yyhhmmss{CR}Ax

xxxxxxxddmmyyh

hmmss

(see Description

of Arguments)