5.2.3.10 CONFIG: Remote

Remote Control: Mode:Serial

SerialConfig EthernetConfig (E)

Use the arrow keys to select Mode, SerialConfig, or EthernetConfig, and then press [ENT].

CONFIG: Remote

Mode

Use the  arrow keys to select Local, Serial, or Serial+Ethernet, and then press [ENT].

Note: Local mode will limit the remote control to only be able to monitor the status of the

modem.

CONFIG: Remote

SerialConfig

Remote Control: Interface Format

Baudrate

(E)

For serial communications, use the arrow keys to select Interface, Format, or Baudrate,

and then press [ENT].

CONFIG: Remote

SerialConfig

Interface

M&C Bus Interface: RS232 RS485-2W

RS485-4W TTL(Switch) CRS-500 (E)

Use the arrow keys to select RS232, RS485-2W (2-wire), RS485-4W (4-wire), TTL

(Switch), or CRS-500, and then press [ENT].

The TTL (Switch) selection enables interoperation with the CRS-311 (1:1) or CRS-300

(1:N) redundancy switches.

Local M&C Bus Address:

0000

When selecting RS-232 the local M&C Bus Address displays 0000.

Addressing is not supported by RS-232 or TTL (Switch) because they are not

multi-drop communication standards. If RS-485 is selected, the display will

show address 0001 to 9999. This address can be changed using the front

panel. The most significant digit is for Comtech EF Data redundancy