beautypg.com

4 test: lamptest, 6 select: save/load – Comtech EF Data SLM-5650A User Manual

Page 124

background image

SLM-5650A Satellite Modem

Revision 8

Front Panel Operation

MN-SLM5650A

5–42

BERT Mode Description
Rx

Select to turn on the receive bit error test set.

Errs

Select to view the absolute number of errors counted.

BER

Select to view the bit error rate as measured by the modem.

The BER function can work with a Fireberd supplying the transmit data test pattern,

while only turning on the Rx Bit Error Rate tester. The transmit test pattern generator

can be turned on at the far end of the link as long as the test patterns match the Rx

BERT. An external bit error test set can be used even when the internal bit error test

set is enabled. If AIS is enabled the data will be overwritten with all ones.

5.2.5.4 TEST: LampTest

Select LampTest to perform a diagnostic run on the front panel LEDs and VFD.

5.2.6 SELECT: Save/Load

Save/Load: Loc:0 Action: View

Empty (E)

Use the arrow keys to select Loc or Action, and then press [ENT].

Option

Settings

Loc

There are 10 locations available [0 – 9]. Use the  arrow keys to select the location to

either save or load a stored configuration, and then press [ENT].

Action

View is the default setting to select and view the location before loading or saving. Otherwise,

select Save or Load at the selected location:

To save a configuration, go through the modem’s menus and configure all the necessary

parameters. Then, select a location, select Save, and then press [ENT].

To load a saved configuration, select the desired configuration, select Load, and then press

[ENT].

Resetting the modem will cause all configurations to be cleared!

Note the following:

If a location has no saved configuration present, the bottom line will display “Empty” as

per the example shown above.

If a location has a configuration saved to it, the bottom line will display the date stamp

for that saved configuration in “HH:MM:SS DD/MM/YY” format: