beautypg.com

Comtech EF Data SLM-5650A User Manual

Page 374

background image

SLM-5650A Satellite Modem

Revision 8

Appendix C

MN-SLM5650A

C–22

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Configured

FAST Options

N/A

16 bytes

Command or Query.
Unit returns information concerning the Configured FAST Options, and the option

field, in the form abcdefghxxxxxxxx, where:

a = QOS: 0 = Not Installed, 1 = Installed

b = Reserved

c = Spectrum Spreading

d = Management Security: 0 = Not Installed, 1 = Installed

e = Vipersat Compatibility: 0 = Not Installed, 1 = Installed

f = Reserved

g = Transec Data Rate Option: 0 = Base (5,000 kbps),

1 = 10,000 kbps, 2 = 20,000 kbps, 3 = 51,840 kbps,

4 = 155,520 kbps, 5 = 2,500 kbps

h = Vipersat Data Rate Option: 0 = Base (5,000 kbps),

1 = 10,000 kbps, 2 = 20,000 kbps, 3 = 51,840 kbps,

4 = 155,520 kbps, 5 = 2,500 kbps

i = Bridged Point to Multipoint: 0 = Not Installed, 1 = Installed

j = Customer Defined Options: 0-3

x = spare

N/A

CFO?

CFO=abcdefghijxx

xxxx
(see Description

of Arguments)

Circuit ID String CID=

24 bytes

Command or Query.
Sets or queries the user-defined Circuit ID string, which is a fixed length of 24

characters.
Valid characters include: Space ( ) * + – , . / 0 9 and A thru Z

CID=

CID?

CID*

CID#

CID?

CID=x

(see Description

of Arguments)

Carrier-in-

Carrier (CnC)

Mode

CNM=

1 byte, value of 0

or 1

Command or Query.
CnC Mode of Operation, where:

0= Off

1= On
Example: CNM=0

CNM=

CNM?

CNM*

CNM#

CNM?

CNM=x

(see Description

of Arguments)

Carrier Only

Test Modes

COM=

1 byte, value of 0

thru 2

Command or Query.
Test Mode, where:

0= Normal Mode (no test)

1=Tx CW

2=Tx Alternating 1,0 Pattern

Example: COM=1 (CW Mode)

COM=

COM?

COM*

COM#

COM?

COM=x

(see Description

of Arguments)

Carrier-in-

Carrier (CnC)

Re-Acquisition

Time

CRA=

3 bytes

Command or Query.
CnC re-Acquisition time in seconds, from 10 to 999. This is the time wherein CnC

will start searching for the delay and frequency offset if a long duration of unlock

occurs.
Example: CRA=010

CRA=

CRA?

CRA*

CRA#

CRA?

CRA=xxx

(see Description