beautypg.com

Comtech EF Data SLM-5650A User Manual

Page 125

background image

SLM-5650A Satellite Modem

Revision 8

Front Panel Operation

MN-SLM5650A

5–43

Save/Load: Loc:0 Action: View

16:18:00 08/07/10 (E)

If a location has a configuration saved, and the user attempts to save a new configuration

to that location, the screen will display the following message:

This configuration contains data. Would

you like to overwrite it?

N

o (E)

The default to this question is No. To overwrite, use the  arrow keys to change the

answer to Yes, and then press [ENT].

A programming sequence message will briefly display, and then the screen will display

the following message before returning back to the Save/Load menu screen:

The current configuration has been saved

to the selected location.

5.2.7 SELECT: Utility

UTILITY: RT-Clk RefAdjust ID Display Temp

Agc Alarm PwrCal Firmware FAST (E)

Use the arrow keys to select RT-Clk, RefAdjust, ID, Display, Temp, Agc, Alarm, Alarm,

PwrCal, Firmware, or FAST, and then press [ENT].

5.2.7.1 Utility: RT-Clk

Edit Real-Time Clock:

15:34:25 27/09/05 (E)

Use the  arrow keys to select and set the Real-Time Clock. Hours are in 24 hour time

(HH:MM:SS) format. The date is shown in DAY/MONTH/YEAR format in accordance with

European format.

5.2.7.2 Utility: RefAdjust

Internal 10 MHz Ref Freq

Fine Adjust: 3F3

(E)

Use the  arrow keys to select and adjust the internal high stability 10 MHz oscillator to

counteract aging. The control value is in hex – not decimal – and has a range of 000 to FFF. The

typical calibration point for a modem is nominally around 400.