Comtech EF Data SLM-5650A User Manual
Page 380
SLM-5650A Satellite Modem
Revision 8
Appendix C
MN-SLM5650A
C–28
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Retrieve next 5
unread Stored
Statistics
N/A
105 bytes
Query only.
Unit returns the oldest 5 Stored Statistics which have not yet been read over the
remote control.
Reply format: {CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-
body, where Sub-body= AA.ABB.Bddmmyyhhmmss,
AA.A = Minimum Eb/No during sample period. “Loss” is displayed if carrier was
lost during the sample period.
BB.B = Average Eb/No during sample period. “Loss” is displayed if carrier was
lost during the entire sample period.
If there are less than 5 events to be retrieved, the remaining positions are padded
with zeros.
If there are no new events, the response is RNS*.
N/A
RNS?
RNS={CR}AA.AB
B.Bddmmyyhhmm
ss{CR}AA.ABB.Bd
dmmyyhhmmss{C
R}AA.ABB.Bddm
myyhhmmss{CR}
AA.ABB.Bddmmy
yhhmmss{CR}AA.
ABB.Bddmmyyhh
mmss
(see Description
for Arguments)
Serial Number
N/A
9 bytes
Query only.
Used to query the unit 9-digit serial number. Unit returns its S/N in the form
xxxxxxxxx.
Example: SNO=176500143
N/A
SNO?
SNO=xxxxxxxxx
(see Description
of Arguments)
Statistics
Sample Interval
SSI=
1 byte
Command or Query.
Used to set the sample interval for the Statistics Logging Function.
SSI=x, where x = 0 to 9 in 10 minute steps.
Note: Setting this parameter to 0 disables the statistics logging function.
Example: SSI=3 sets the logging inverval to 30 minutes
SSI=
SSI?
SSI*
SSI#
SSI?
SSI=x
(see Description
of Arguments)
Software
Revision
N/A
43 bytes
Query only.
Unit returns the value of the internal software revision installed in the unit, in the
form:
Boot:xx.yy.zz Bulk1:xx.yy.zz Bulk2:xx.yy.zz
Example: SWR=Boot:01.01.01 Bulk1:01.01.01 Bulk2:01.01.01
N/A
SWR?
SWR=Boot:xx.yy.
zz Bulk1:xx.yy.zz
Bulk2:xx.yy.zz
(see Description
of Arguments)
RTC Time
TIM=
6 bytes
Command or Query.
A time in the form hhmmss, indicating the time from midnight, where:
hh = hours (00 to 23)
mm = minutes (00 to 59)
ss = seconds (00 to 59)
Example: TIM=231259 (23 hours:12 minutes:59 seconds)
TIM=
TIM?
TIM*
TIM#
TIM?
TIM=hhmmss
(see Description
of Arguments)
Temperature
N/A
3 bytes
Query only.
Unit returns the value of the internal temperature, in the form of xxx (degrees C).
Example: TMP=+26
N/A
TMP?
TMP=xxx
(see Description