Comtech EF Data SLM-5650A User Manual
Page 119

SLM-5650A Satellite Modem
Revision 8
Front Panel Operation
MN-SLM5650A
5–37
5.2.4.2 Monitor: Event-Log
Stored Events: View Clear-All
ModemParameters(E)
Use the
arrow keys to select View, Clear-All, or ModemParameters, and then press [ENT].
Monitor: Event-Log
View
Event 001:003 1:43:02 27/09/05
Mod: ---- ++ --
(E)
To view the details of a stored fault, first use the arrow keys to scroll
through the event numbers, and then press [ENT] to select. Then, use the
arrow keys to navigate the listed fault character positions, displayed on the
bottom line, to view the fault description If the faulted listed is Power On or
Power Off, nothing will be displayed if that event is selected.
Monitor: Event-Log
Clear-All
Clear All Stored Events? No Yes
(E)
Use the arrow keys to select No (to retain) or Yes (to clear all) stored faults, and
then press [ENT].
Monitor: Event-Log
ModemParameters
Current Temp: +41 Max Temp: +56
Comp Power< -70.0 Max Power> +25.0 (E)
This read-only screen displays the unit’s Current Temperature, Max Temp, Comp Power and
Max Power. Press [ENT] or [CLR] to return to the previous menu.