C.6.1 Initial Setup – Priority Commands / Queries
Before executing any Modem, Unit, Bulk/Global, AUPC, or Optional Interface commands/queries, initial setup should be accomplished with these
three commands, prioritized as follows: (Highest Priority) MOM, RFB, ITF (Lowest Priority). Priority commands are indicated by
shading
throughout these sections. Any change to a higher priority parameter can override any of the parameters of lower priority.
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Modem
Operating
Mode
MOM=
1 hex byte,
value 0 thru C
Command or Query.
Modem Operating Mode, where:
x = 0=OM-73
1=Mil-165A
2=IESS-308
3=IESS-309
4=IESS-310
5=TURBO
6=16QAM
7=AUPC
8=RXBURST
9=TXBURST
A=TURBO-FA
B=RXBRSTFA
C=LDPC
Example: MOM=0 (sets OM-73 operating mode)
MOM=
MOM?
MOM*
MOM#
MOM?
MOM=x
(see Description
of Arguments)
Modem RF
Band
RFB=
1 byte, value 0
or 1
Command or Query.
Modem RF Band, where:
0=70/140 MHz Band
1=L-Band (950 MHz – 2000 MHz)
Example: RFB=0 (sets 70/140 Band)
RFB=
RFB?
RFB *
RFB #
RFB?
RFB =x
(see Description
of Arguments)
Interface Type ITF=
1 byte, value 0
thru 7
Command or Query.
Interface Type, where:
0=EIA-530
1=HSSI
2=Unbalance G.703
3=Balanced G.703
4=GigaBit Ethernet Interface
6=Network Processor Card
7=LVDS Interface
Example: ITF=0 (sets EIA-530 interface type)
ITF=
ITF?
ITF*
ITF#
ITF?
ITF=x
(see Description
of Arguments)