beautypg.com

Comtech EF Data SLM-5650A User Manual

Page 364

background image

SLM-5650A Satellite Modem

Revision 8

Appendix C

MN-SLM5650A

C–12

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Tx Scrambler

TSC=

1 byte, value of 0

thru 6

Command or Query.
Tx Scrambler state, where:

0 = Off

1 = OM-73 Scrambler

2 = V.35 Scrambler

3 = Modified V.35 (Comtech EF Data Closed Network)

4 = Reed-Solomon Synchronous Scrambler

5 = IBS Overhead Synchronous Scrambler

6 = TURBO Scrambler

Depending on Modem mode, FEC type, overhead type, and RS state, not all

selections will be valid.
Example: TSC=1 (OM-73 Scrambler On)

TSC=

TSC?

TSC*

TSC#

TSC?

TSC=x

(see Description

of Arguments)

Tx Spreading

Equation

TSE=

1 byte, value of 1

thru 4

Command or Query.
Tx Spreading Equation, where x selects Equation 1 thru 4:
Example: TSE=1 (Tx Equation #1)

TSE=

TSE?

TSE*

TSE#

TSE?

TSE=x

(see Description

of Arguments)

Tx Spreading

Factor

TSF=

3 bytes, value of

1 thru 128

Command or Query.
Tx Spreading Factor, where xxx is value from 1 to 128. Values other than 1 are only

valid when Modem Type = LDPC.
Example: TSF=001 (Tx Spreading Off)

TSF=

TSF?

TSF*

TSF#

TSF?

TSF=xxx

(see Description

of Arguments)

Tx Spectrum

Invert

TSI=

1 byte, value of 0

or 1

Command or Query.
Tx Spectrum Invert selection, where:

0=Normal,

1=Tx Spectrum Inverted

Example: TSI=0 (selects normal)

TSI=

TSI?

TSI*

TSI#

TSI?

TSI=x

(see Description

of Arguments)

Live Tx Faults

N/A

8 bytes

Query only.
Live Tx Faults are returned as a 32 bit Hexadecimal value. Bit values are defined as

follows:

80000000 = Modulator Symbol Clock not locked

40000000 = Modulator RF Synthesizer not locked

20000000 = Modulator No IQ Activity

10000000 = Modulator Nyquist Filter Clipping

08000000 = Interface data clock PLLs not locked

04000000 = Interface Terrestrial Clock No Activity

02000000 = Interface SCT PLL not locked

01000000 = Interface No Data Activity

Example: TXF=00000000 indicates No Tx Faults

N/A

TXF?

TXF=xxxxxxxx

(see Description