beautypg.com

Comtech EF Data SLM-5650A User Manual

Page 376

background image

SLM-5650A Satellite Modem

Revision 8

Appendix C

MN-SLM5650A

C–24

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Equipment ID

N/A

17 bytes

Query only.
Unit returns information concerning the equipment identification, and the option field,

in the form aaaabcdefghijklmx where:

aaaa = defines the modem model number (565A = SLM-5650 in this case)

b = Advanced FEC: 0 = None, 1 = TPC, 2 = TPC + LDPC

c = Advanced FEC Data Rate: 0 = Base (5,000 kbps),

1 = 10,000 kbps, 2 = 20,000 kbps, 3 = 51,840 kbps, 4 = 155,520 kbps,

5 = 2,500 kbps

d = Option Card: 0 = None, 1 = G.703, 2 = GigaBit Ethernet,

4 = Network Processor, 5 = LVDS

e = Data Rate (Asymmetric Tx) Option: 0 = Base (5,000 kbps),

1 = 10,000 kbps, 2 = 20,000 kbps, 3 = 51,840 kbps,

4 = 155,520 kbps, 5 = 2,500 kbps

f = Higher-order modulation: 0 = None, 1 = 8PSK, 2 = 8PSK and 16QAM,

3 = 8PSK+16QAM and 16APSK/32APSK

g = Reed-Solomon Codec Option: 0 = None, 1 = Installed

h = Transec Module: 0 = None, 1 = FEC2 Card and Transec Module Installed,

2 = FEC2 Card Installed (No Transec)

i = AUPC Option: 0 = None, 1 = Installed

j = ASYNC Engineering Service Channel: 0 = None, 1 = Installed

k = Demod Only

l = CnC Data Rate: 0 = None, 1 = up to 512 kbps, 2 = up to 1 Mbps,

3 = up to 2.5 Mbps, 4 = up to 5 Mbps, 5 = up to 10 Mbps, 6 = up to 15 Mbps,

7 = up to 20 Mbps, 8 = up to 25 Mbps, 9 = up to 30 Mbps, A = up to 40 Mbps,

B = up to 51.840 Mbps, C = up to 70 Mbps

m = Sequential Encoding/Decoding Option: 0 = None, 1 = Installed

x = Asymmetric Rx Data Rate: 0 = None, 1 = 10,000 kbps, 2 = 20,000 kbps,

3 = 51,840 kbps, 4 = 155,520 kbps, 5 = 2,500 kbps

Example: EID=565A0000000000000 indicates SLM-5650A with no options installed

N/A

EID?

EID=aaaabcdefghi

jklmx

(see Description

of Arguments)

Initialize Events

Pointer

IEP=

None

Command only.
Resets internal pointer to allow RNE? queries to start at the beginning of the stored

events log.

IEP=

IEP#

N/A

N/A

Software Image IMG=

1 bytes, value of

1 or 2

Command or Query.
Next Reboot Image, where:

1 = Bulk Image #1

2 = Bulk Image #2

Example: IMG=1 (Image #1 will be active after next reboot)

IMG=

IMG?

IMG*

IMG#

IMG?

IMG=x

(see Description

of Arguments)