Command
Parameter
^RS
Resynchronizes supply when supply roll is changed.
Note:
Printer ignores this command if printing.
^SD or ^SCd Disables the status polling feature by turning off the status polling control character.
Sets the status polling control character to the ASCII value given by the d parameter.
The value of d can be any ASCII character.
^TP
Prints a test label.
Note:
Printer ignores this command if printing.
Note:
To use the immediate command control character or the status
polling character within your data, use the tilde sequence.
D e f i n i n g t h e C o m m u n i c a t i o n S e t t i n g s P a c k e t
Use the communication settings packet (F) to set the baud rate, word
length, stop bits, parity, and flow control for serial communications.
Changing the communication settings takes approximately two seconds.
Communications sent during this interval will be lost. Make sure the host
communication values match the values on the printer and the host is
capable of communicating at the speed you select for the printer.
Do not add any characters, such as a carriage return/line feed, in your
communication settings packet or communications errors may occur.
Syntax
{
I,F,baud,word_length,stop_bits,par ity,
flow_con trol
p }
F1. F
Communication Settings Packet
F2. baud
Baud Rate. Options:
0 1200
1 2400
2 4800
3 9600 (default)
4 19200
5 38400
F3. word_length
Word Length. Options:
0
7-bit word length (odd or even parity only)
1
8-bit word length (default)
F4. stop_bits
Stop Bits. Options:
0
1-stop bit (default)
1
2-stop bits
2-18 Configuring the Printer