264
Secondary symbol selection must be 0 (none) or 1 (print
secondary sign).
265
Monetary decimal places must be 0 to 3.
266
Character string length in the control characters packet must be 5
(MPCL control characters) or 7 (ENQ/IMD command character).
267
Baud rate selection must be 0 (1200), 1 (2400), 2 (4800), 3
(9600), 4 (19200), or 5 (38400). Resend the communication
settings packet.
268
Word length selection must be 0 (7 bits), or 1 (8 bits). Resend the
communication settings packet.
269
Stop bits selection must be 0 (1 bit), or 1 (2 bits). Resend the
communication settings packet.
270
Parity selection must be 0 (none), 1 (odd), or 2 (even). Resend
the communication settings packet.
271
Flow control selection must be 0 (none), 1 (DTR), 2 (CTS/RTS), or
3 (XON/XOFF). Resend the communication settings packet.
272
Symbol set (code page) in the System Setup packet must be
0 (Internal), 1 (ANSI), 2 (DOS 437), 3 (DOS 850), 4 (1250- Latin
2), 5 (1251- Cyrillic), 6 (1252- Latin 1), 7 (1253- Greek), 8 (1254-
Turkish), 9 (1255- Hebrew), 10 (1256- Arabic), 11 (1257- Baltic),
12 (1258- Vietnamese), 13 (852- Latin 2), 14 (855- Russian), 15
(857- IBM Turkish), 16 (860- DOS Portuguese), 17 (Wingdings),
18 (Macintosh), or 19 (Unicode).
282
RS232 Trailer string is too long. Use a maximum of 3 characters.
283
ENQ Trailer string is too long. Use a maximum of 3 characters.
284
The buffer type must be D (Downloadable Fonts), F (Format), I
(Image), R (Receive), T (Transmit), or V (Scalable Fonts).
285
The storage device type in the memory configuration packet must
be F (flash) or R (volatile RAM).
286
The buffer size is invalid.
Diagnostics and Errors 8-11