beautypg.com

Defining the batch control field 6-3, Defining batch data fields 6-3, Defining 6-3 – Avery Dennison Sierra Sport2 9460 Programmer Manual User Manual

Page 111: Syntax 6-3, Sample 6-3, For batch 6-3, Batch control field 6-3, Batch data field 6-3, Feed mode selection 6-3, Batch control syntax 6-3

background image

D e f i n i n g t h e B a t c h C o n t r o l F i e l d

The batch header must precede this field. The batch control field defines
the print job and applies only to the batch that immediately follows.

Syntax

E,feed_mode,batch_sep,print_mult,multi_part

p

E1. E

Batch Control Field.

E2. feed_mode

Feed Mode. Options:

0

Continuous Feed (default)

1

On-Demand

E3. batch_sep

Batch Separator. Use 0 (no separator).

E4. print_mult

Number of tags (1 to 999) with the same image. 0 is the default.

E5. multi_part

Number of identical parts on one tag (1 to 5). 0 is the default.

Example

E,0,1,1

p

Defines a batch control field. Continuous feed mode is used and no
separator prints between batches.

D e f i n i n g B a t c h D a t a F i e l d s

Batch data fields should be sent in field number order. Use continuation
fields for large amounts of data. If you are using N (New) in the batch
header, you must list all fields with your data in sequence. If you are using
U, you need to list only those fields and data that changes from the last
printed batch.

Syntax

field#,"data string"

p

C,"continuation"

p

field#

Identifies the text, bar code, or non-printable text field in which to insert the
following data. Range: 1 to 999.

“data string”

Provides the actual information to appear in fields. Enclose in quotation
marks. Length: 0 to 2710 characters

.

C

Identifies information to be appended to the data string. This parameter is
optional.

Printing 6-3