2 power requirements, Table 2-3, Power requirements – Artesyn ATCA-7365 Installation and Use (May 2014) User Manual
Page 52: Hardware preparation and installation

Hardware Preparation and Installation
ATCA-7365 Installation and Use (6806800K65M)
52
2.2.2
Power Requirements
The blade's power requirements depend on the installed hardware accessories. If you want to
install accessories on the blade, the load of the respective accessory has to be added to that of
the blade. In the following table you will find typical examples of power requirements with and
without accessories installed. For information on the accessories' power requirements, refer to
the documentation delivered together with the respective accessory or consult your local
Artesyn representative for further details.
The blade must be connected to a TNV-2 or a safety-extra-low-voltage (SELV) circuit. A TNV-2
circuit is a circuit whose normal operating voltages exceed the limits for a SELV circuit under
normal operating conditions, and which is not subject to overvoltages from
telecommunication networks.
Table 2-3 Power Requirements
Characteristic
Value
Rated Voltage
Exception in the US and Canada
-48 VDC to -60 VDC
-48 VDC
Operating Voltage
Exception in the US and Canada
-39 VDC to -72 VDC
-39 VDC to -60 VDC
Max. power consumption of ATCA-7365 (with RTM-
ATCA-7360 including a SAS HDD)
260 W
(200 W typical)
Max. power consumption of ATCA-7365 (without RTM-
ATCA-7360 )
240 W
(185 W typical)