Table 4-35, Post error event format, Table 4-36 – Artesyn ATCA-7365 Installation and Use (May 2014) User Manual
Page 134: Result first dword supported post errors, Table 4-37, Result second dword supported post errors, Bios
BIOS
ATCA-7365 Installation and Use (6806800K65M)
134
A set bit at a Result DWORD bit position implies that the error associated with that position has
occurred. If there was an error which has no corresponding bit in the Result DWORDs, the bit 0
from the Second DWORD is set (OEM: Unspecified Error).
Table 4-35 POST Error Event Format
Offset
Name
Format
Description
00h
Event Type
BYTE
Event Type = 02h
01h
Length
BYTE
always 0Ch
02h-07h
Date/Time Fields
BYTE
These fields contain the BCD
representation of the date and time
08h-0Bh
Result First DWORD
UINT32
0Ch-0Fh
Result Second DWORD
UINT32
Table 4-36 Result First DWORD supported POST Errors
Bit
Description
3
CMOS RAM Battery Failure. Battery is bad, removed or replaced.
9
Keyboard Not Functional. No console input device found or device error.
12
Memory Decreased in Size. DIMM errors during memory initialization found.
Failed DIMM disabled.
18
RTC Time Not Set. Found invalid Date/Time. Date/Time reset to a valid default
value.
8
OEM: IPMI failure
29
OEM: IPMI Boot Parameter read/write error
30
OEM: IPMI Boot Parameter checksum error
31
OEM: IPMI Boot Parameter locked
Table 4-37 Result Second DWORD supported POST Errors
Bit
Description
0
OEM: unspecified error
1
OEM: North Bridge error