beautypg.com

Fru information and sensor data records, Table 9-8 sensor data records (continued) – Artesyn ATCA-7365 Installation and Use (May 2014) User Manual

Page 285

background image

FRU Information and Sensor Data Records

ATCA-7365 Installation and Use (6806800K65M)

285

49

Battery

Battery
0x29

Sensor-specific
discrete
0x6F

0x1

0xFF

0xFF

0x1: Battery failed

Asrt

Auto

50

48V A Supply

Power Supply
0x08

Sensor-specific
discrete
0x6F

0x0
0x1

See IPMI Spec

0xFF

0x0: Presence detected
0x1: Power Supply Failure

detected

Asrt / Deass

Auto

51

48V B Supply

Power Supply
0x08

Sensor-specific
discrete
0x6F

0x0
0x1

See IPMI Spec

0xFF

0x0: Presence detected
0x1: Power Supply Failure

detected

Asrt / Deass

Auto

Table 9-8 Sensor Data Records (continued)

Sensor

Number

Sensor Name

Sensor Type

Event/Reading

Type

Event

Data

Byte 1

Event Data Byte 2

Event Data Byte 3

Event Threshold/Description

Assertion

Deassertion

Rearm

Asrt: Assertion Unr: Upper non-recoverable threshold Uc: Upper critical threshold Unc: Upper non-critical threshold
Deass: Deassertion Lnr: Lower non-recoverable threshold Lc: Lower critical threshold Lnc: Lower non-critical threshold