FRU Information and Sensor Data Records
ATCA-7365 Installation and Use (6806800K65M)
285
49
Battery
Battery
0x29
Sensor-specific
discrete
0x6F
0x1
0xFF
0xFF
0x1: Battery failed
Asrt
Auto
50
48V A Supply
Power Supply
0x08
Sensor-specific
discrete
0x6F
0x0
0x1
See IPMI Spec
0xFF
0x0: Presence detected
0x1: Power Supply Failure
detected
Asrt / Deass
Auto
51
48V B Supply
Power Supply
0x08
Sensor-specific
discrete
0x6F
0x0
0x1
See IPMI Spec
0xFF
0x0: Presence detected
0x1: Power Supply Failure
detected
Asrt / Deass
Auto
Table 9-8 Sensor Data Records (continued)
Sensor
Number
Sensor Name
Sensor Type
Event/Reading
Type
Event
Data
Byte 1
Event Data Byte 2
Event Data Byte 3
Event Threshold/Description
Assertion
Deassertion
Rearm
Asrt: Assertion Unr: Upper non-recoverable threshold Uc: Upper critical threshold Unc: Upper non-critical threshold