beautypg.com

Table 8-22, Request data of get serial output command, Table 8-23 – Artesyn ATCA-7365 Installation and Use (May 2014) User Manual

Page 248: Response data of get serial output command, Supported ipmi commands

background image

Supported IPMI Commands

ATCA-7365 Installation and Use (6806800K65M)

248

8.3.1.2.1 Request Data

The following table lists the request data applicable to the Get Serial Output command.

8.3.1.2.2 Response Data

The following table lists the response data applicable to the Get Serial Output command.

Table 8-22 Request Data of Get Serial Output Command

Byte

Data Field

1

LSB of Artesyn Embedded Technologies IANA Enterprise number. A value of 0xCD has
to be used.

2

Second byte of Artesyn Embedded Technologies IANA Enterprise number. A value of
0x65 has to be used.

3

MSB of Artesyn Embedded Technologies IANA Enterprise number. A value of 0x00 has
to be used.

4

Serial connector type
0: Face plate connector
1: Backplane connector
All other values are reserved.
Note: Only the faceplate connector is supported. No connector on the RTM available.

5

Serial connector instance number. A sequential number that starts from 0.

Table 8-23 Response Data of Get Serial Output Command

Byte

Data Field

1

Completion code

2

LSB of Artesyn Embedded Technologies IANA Enterprise number.

3

Second byte of Artesyn Embedded Technologies IANA Enterprise number.

4

MSB of Artesyn Embedded Technologies IANA Enterprise number.

5

Serial output selector