beautypg.com

4 power configuration, 5 sensor data records, 4 power configuration 9.5 sensor data records – Artesyn ATCA-7365 Installation and Use (May 2014) User Manual

Page 274: Table 9-6, Power configuration, Table 9-7, Ipmi sensors overview, Fru information and sensor data records

background image

FRU Information and Sensor Data Records

ATCA-7365 Installation and Use (6806800K65M)

274

9.4

Power Configuration

9.5

Sensor Data Records

The sensors available on the blades are shown in the table below. See the

Table 9-8 on page 278

for a detailed description of the Sensor Data Records.

Table 9-6 Power Configuration

Item Value

Description

Dynamic power
reconfiguration support

No

While the blade is powered, it
supports only one power level.

Dynamic power
configuration

No

The power level is fixed and does
not change).

Number of power draw
levels

2

The amount of possible power
levels

Early Power Draw Levels,
Watt

-

Complete early power level
including IPMC

Steady state Power Draw
Levels, Watt

2.0 GHz 6x4GB DDR3 + RTM =
180 - 220 Watts
Max - 260 Watts

Complete steady power
consumption including IPMC

Transition from early to
steady levels, sec

0s

-

Table 9-7 IPMI Sensors Overview

Sensor Name

Sensor Type

Sensor
Number

1.2V

Voltage

0x0A

1.5V

Voltage

0x09

1.5V DDR3

Voltage

0x0C

1.8V Eth

Voltage

0x08

12.0V

Voltage

0x05