Fru information and sensor data records – Artesyn ATCA 7370 / ATCA 7370-S Installation and Use (June 2014) User Manual
Page 234

FRU Information and Sensor Data Records
ATCA-7370/ATCA-7370-S Installation and Use (6806800P54F)
234
7
PWR Status OEM
0xD7
Sensor-
specific
discrete
0x6F
0x0
Synchor Pwr Entr
Module:
[6] = VOUT_low
[5] = Hotswap
[4] = Holdup
[2] = Alarm
[1] = Enable_B
[0] Enable_A
Emerson Pwr Entry
Module:
[7] = DIG_Fault
[6] = HUCapEngage
[5] = Hotswap_Enable
[4] = HUCap_Switch
[3] = Alarm_Control
[1] = DIG_Alarm
[0] = Sec_MCU_Fault
All other bits are
reserved
[7:6] = Pwr Entry
Module
0 = Synchor
1 = Emerson
Emerson Pwr
Entry Module:
[2] = DIG_EnableA
[1] = DIG_EnableB
[0] = Mcu_Fault
All other bits are
reserved
0x0: Pwr Entry
Module Status
Change detected
Asrt
Auto
8
Inlet Temp
Temp
0x01
Threshold
0x01
reading
threshold
unr uc unc
Asrt / Deass Auto
9
Outlet Temp Temp
0x01
Threshold
0x01
reading
threshold
unr uc unc
Asrt / Deass Auto
10
Board Temp Temp
0x01
Threshold
0x01
reading
threshold
unr uc unc
Asrt / Deass Auto
Table 9-3 Sensor Data Records (continued)
Sensor
Number Sensor Name Sensor Type
Event/Reading
Type
Event
Data
Byte 1 Event Data Byte 2
Event Data Byte 3
Event Threshold/
Description
Assertion
Deassertion Rearm