Table 9-3, Sensor data records, Fru information and sensor data records – Artesyn ATCA 7370 / ATCA 7370-S Installation and Use (June 2014) User Manual
Page 232
FRU Information and Sensor Data Records
ATCA-7370/ATCA-7370-S Installation and Use (6806800P54F)
232
For sensor threshold definition please use the "ipmitool" found on
http://sourceforge.net/projects/ipmitool/files/ipmitool/
with
the parameter "sensor".
Table 9-3 Sensor Data Records
Sensor
Number Sensor Name Sensor Type
Event/Reading
Type
Event
Data
Byte 1 Event Data Byte 2
Event Data Byte 3
Event Threshold/
Description
Assertion
Deassertion Rearm
0
HS Carrier
Hot Swap
0xF0
Sensor-
specific
discrete
0x6F
0x0
0x1
0x2
0x3
0x4
0x5
0x6
0x7
[7:4] = Cause
[3:0] = Previous State
FRU ID
0x0: M0
0x1: M1
0x2: M2
0x3: M3
0x4: M4
0x5: M5
0x6: M6
0x7: M7
Asrt
Auto
1
Hot Swap
RTM
Hot Swap
0xF0
Sensor-
specific
discrete
0x6F
0x0
0x1
0x2
0x3
0x4
0x5
0x6
0x7
[7:4] = Cause
[3:0] = Previous State
FRU ID
0x0: M0
0x1: M1
0x2: M2
0x3: M3
0x4: M4
0x5: M5
0x6: M6
0x7: M7
Asrt
Auto
2
-48V A Volts Voltage
0x02
Threshold
0x01
reading
threshold
unr uc lnr lc
Asrt / Deass Auto
3
-48V B Volts Voltage
0x02
Threshold
0x01
reading
threshold
unr uc lnr lc
Asrt / Deass Auto