Syntax, Argument – ADLINK PCI-8164 User Manual
Page 233

Function Library
221
@ Syntax
C/C++ (DOS, Windows 95/NT/2K/XP)
I16 _8164_set_alm(I16 AxisNo, I16 alm_logic, I16
alm_mode);
I16 _8164_set_el(I16 AxisNo, I16 el_mode);
I16 _8164_set_inp(I16 AxisNo, I16 inp_enable, I16
inp_logic);
I16 _8164_set_erc(I16 AxisNo, I16 erc_logic, I16
erc_on_time);
I16 _8164_set_servo(I16 AxisNo, I16 on_off);
I16 _8164_set_sd(I16 AxisNo, I16 enable, I16
sd_logic, I16 sd_latch, I16 sd_mode);
Visual Basic (Windows 95/NT/2K/XP)
B_8164_set_alm (ByVal AxisNo As Integer, ByVal
alm_logic As Integer, ByVal alm_mode As
Integer) As Integer
B_8164_set_el (ByVal AxisNo As Integer, ByVal
el_mode As Integer) As Integer
B_8164_set_inp (ByVal AxisNo As Integer, ByVal
inp_enable As Integer, ByVal inp_logic As
Integer) As Integer
B_8164_set_erc (ByVal AxisNo As Integer, ByVal
erc_logic As Integer, ByVal erc_on_time As
Integer) As Integer
B_8164_set_servo (ByVal AxisNo As Integer, ByVal
On_Off As Integer) As Integer
B_8164_set_sd (ByVal AxisNo As Integer, ByVal
enable As Integer, ByVal sd_logic As
Integer, ByVal sd_latch As Integer, ByVal
sd_mode As Integer) As Integer
@ Argument
AxisNo: Designated axis number to configure
alm_logic: Setting of active logic for ALARM signals
X
alm_logic=0, active LOW
X
alm_logic=1, active HIGH