ADLINK PCI-8164 User Manual
Page 173

Motion Creator
161
Z
In Manual Pulser Move, this causes the axis to go into
pulse move. The speed limit is the value set by Maxi-
mum Velocity.
Z
Right play button: Click this button to let the card start
to outlet pulses according to previous setting.
Z
In Absolute Mode, this causes the axis to move to posi-
tion.
Z
In Relative Mode, this causes the axis to move back-
wards.
Z
In Cont. Move, this causes the axis to start to move
according to the velocity setting, but in the opposite
direction.
Z
In Manual Pulser Move, this causes the axis to go into
pulse move. The speed limit is the value set by Maxi-
mum Velocity.
16.Change Position On The Fly Button: When enabled,
you can change the target position of the current
motion. The new position must be defined in Position2.
The related function is _8164_p_change().
17.Change Velocity On The Fly Button: When enabled,
you can change the velocity of the current motion. The
new velocity must be defined in Maximum Velocity. The
related function is _8164_v_change()
18.Stop Button: Clicking this button causes the card to
decelerate and stop. The deceleration time is defined in
Decel. Time. The related function is
_8164_sd_stop().
19.I/O Status: The status of motion I/O. Light-On means the
motion I/O is active while Light-Off indicates inactivity.
The related function is _8164_get_io_status().