ADLINK PCI-8164 User Manual
Page 172

160
Motion Creator
100.0. In Cont. Move, both the value and sign are effec-
tive.
–100.0 means 100.0 in the minus direction.
Z
Maximum Velocity: Sets the maximum velocity of
motion in units of PPS. In Absolute Mode or Relative
Mode, only the value is effective. For example, -5000.0
is the same as 5000.0. In Cont. Move, both the value
and sign is effective. –5000.0 means 5000.0 in the
minus direction.
Z
Accel. Time: Sets the acceleration time in units of sec-
ond.
Z
Decel. Time: Sets the deceleration time in units of sec-
ond.
Z
SVacc: Sets the S-curve range during acceleration in
units of PPS.
Z
SVdec: Sets the S-curve range during deceleration in
unit sof PPS.
Z
Move Delay: This setting is available only when repeat
mode is On. It causes the card to delay for a specified
time before it continues to the next motion.
13.Speed Range: Sets the max speed of motion. When you
select Not Fix, the Maximum Speed automatically
becomes the maximum speed range, which can not be
exceeded by on-the-fly velocity change.
14.Servo On: Sets the SVON signal output status. The
related function is _8164_set_servo().
15.Play Key:
Z
Left play button: Clicking this button lets the card start
to outlet pulses according to previous setting.
Z
In Absolute Mode, this causes the axis to move to
position1.
Z
In Relative Mode, this causes the axis to move forward.
In Cont. Move, this causes the axis to start to move
according to the velocity setting.