4 pulse input/output configuration, Pulse input/output configuration – ADLINK PCI-8164 User Manual
Page 191

Function Library
179
6.4 Pulse Input/Output Configuration
@ Name
_8164_set_pls_outmode – Set the configuration for pulse
command output.
_8164_set_pls_iptmode – Set the configuration for feedback
pulse input.
_8164_set_feedback_src – Enable/Disable the external feed-
back pulse input
@ Description
_8164_set_pls_outmode:
Configures the output modes of command pulses. There are six
modes for command pulse output.
_8164_set_pls_iptmode:
Configures the input modes of external feedback pulses. There
are four types for feedback pulse input. This functionis only avail-
able when the Src parameter in _8164_set_feedback_src()
function is enabled.
_8164_set_feedback_src:
If external encoder feedback is available in the system, enable the
Src parameter in this function. The internal 28-bit up/down
counter counts according to the configuration of the
_8164_set_pls_iptmode() function. Otherwise, the counter
will count the command pulse output.
@ Syntax
C/C++ (DOS, Windows 95/NT/2K/XP)
I16 _8164_set_pls_outmode(I16 AxisNo, I16
pls_outmode);
I16 _8164_set_pls_iptmode(I16 AxisNo, I16
pls_iptmode, I16 pls_logic);
I16 _8164_set_feedback_src(I16 AxisNo, I16 Src);