beautypg.com

ADS Environmental Services ADS TRITON+ QR 775027 A3 User Manual

Page 75

background image

3-14 ADS TRITON+ Manual

5. Slide the Surface Combo/Ultrasonic Depth Sensor mounting

plate onto the open end of the ring with the back of the
mounting plate (side with the slots) facing the outside of the
ring. The side with the keyholes should face the inside of the
ring. The end of the plate with the keyholes should be
extending out from the upstream edge of the ring (opposite the
edge with the holes for securing the sensor cable).

Sliding the Surface Combo/Ultrasonic Depth Sensor mounting plate onto the

ring

Note: For applications that involve replacing a previous
version of the Ultrasonic Depth Sensor (for example, ADS
p/n 8K-CS3-V0-XX-30) with a new Ultrasonic Depth
Sensor (ADS p/n 8K-CS5-D1-00-30) or Surface Combo
Sensor and an existing ring remains assembled and secured
in the pipe, use a sliding adapter bracket (ADS p/n 8000-
0299) to accommodate the new sensor in the existing
sensor mounting plate. Once the previous sensor has been