background image

Modbus

9-7

XBUS

CABLE GLAND

RS-232 CABLE

Running RS-232 cable through left cable gland in XBUS

2. (applicable only when using a custom cable or after removing

a DB-9 connector from a pre-fabricated cable) Strip and
separate the wires from the cable and attach/re-attach the DB-9
connector to the cable based on the pin-out referenced in the
following table:

Pin

Name

Direction

Notes

1

DCD

Input

2

RX

Output

3

TX

Input

4

DTR

Input

5

GND

6

DSR

Internally connected to RTS and CTS

7

RTS

Internally connected to DSR and CTS