beautypg.com

ADS Environmental Services ADS TRITON+ QR 775027 A3 User Manual

Page 385

background image

A-4

ADS TRITON+ Manual

represents the actual entities plus one date/time stamp. A
date/time stamp must be included for each monitoring point
associated with the monitor.

Peak Combo

Sensor

Surface Combo

Sensor

Ultrasonic Depth

Sensor

7

6

3

• Deduct 2 to 3 days from the total days of storage to compensate

for additional overhead in memory.

Following is the equation for calculating the total days of storage
available in the monitor memory:

Data Storage Available in the Monitor (in Bytes)

=

Total Days of

Storage in

the Monitor

Memory

Number of

Readings

Taken per

Day for

One entity

X

Memory

Consumed for

One Entity

Reading

(Date/Time

Stamp)

X

Number of

Entities Logged

by the Monitor

(based on the

selected
devices)

For example, recording data at a 15-minute sample rate using a
Peak Combo Sensor offers approximately 150 days of data storage.

851,968 bytes

=

158 days (150

when accounting for

overhead)

96 readings

X

8 bytes

X 7 entities (including

1 for the date/ time

stamp)