10-4 ADS TRITON+ Manual
Make sure all connector ports on the monitor top are dry. Use
compressed air or paper towels to dry out wet or damp
connectors. Note and replace missing interfacial seals in the
sensor connector ends. As a temporary measure, the
connectors can be protected against moisture by wrapping with
self-vulcanizing rubber stretch tape. Make sure covers are
securely in place on any unused ports on the monitor top.
Confirming the Monitor
Confirm the accuracy of the sensor subsystems in the monitor on a
regular basis through Qstart. Confirmation involves comparing
manually-measured depth of flow and velocity readings to the
monitor's readings. This process also verifies sensor parameters.
Refer to the Qstart online help for detailed information on
performing confirmation procedures.
Obtaining Diagnostic Codes from the Monitor
The TRITON+ enables you to observe monitor activity, view
diagnostic information, and confirm test cryouts from the monitor
through a small LED status window on the monitor top. The
numbers/characters displayed represent specific codes indicating
current processes, identification, status, or readings associated with
the system and communications. The following sections contain
general descriptions and interpretations of the diagnostic
information available through the LED and instructions for
accessing information or prompting a message.