A-1

A P P E N D I X A

Specifications

This appendix contains specifications for the ADS

TRITON+

flow monitor and associated subassemblies, sensors, cables, and the
external power, Modbus, and I/O hardware.

TRITON+ Flow Monitor (ADS p/n 8000-FST-IM)

Enclosure

Cylindrical 0.37-inch (6.39-mm) thick, seamless,
plastic canister with stainless steel threaded
inserts

Aluminum end-cap attached to canister with four
stainless steel bolts and a gasket interface

Meets NEMA6P/IP68 standard

Dimensions

17.75 inches (451 mm) long by 8.75 inches (222
mm) maximum diameter 6.63 inches (168 mm)
minimum diameter

Weight

30.3 pounds (13.7 kg) (with 12-volt battery pack)

Operating /

Storage

Temperature

Operating: -4

° to 140° F (-20° to 60° C)

Storage: -4

° to 167° F (-20° to 75° C)