Gathering Parts and Supplies
Obtain the following supplies before installing the ring and sensors
to prevent any costly delays. When ordering, specify the TRITON+
flow monitor installation hardware for ring mounting. In addition,
please indicate the type of mounting hardware desired for mounting
the monitor: mounting bracket (wall/rim mount) or hook (rung
mount).
Quantity
Description
ADS P/N
1
TRITON+ flow monitor (battery or externally-
powered)
8000-FST-IM-GL or
8000-FST-IM-EP-
GL
1
1
Monitor mounting bracket/flange (for mounting
monitor to manhole rim or wall)
I40
–0009
3
Monitor mounting bracket bolt, hex, SS, M8 x
30mm
508058
3
Monitor mounting bracket washer, flat, SS
517-8001254-00
3
Monitor mounting bracket washer, split lock,
SS
517-8001274-00
1 as
needed
Hook, SS, 2-piece w/ hardware
(for hanging monitor on manhole rung;
Alternative to ADS p/n I40-0009)
8000-0021
1 as
needed
Bracket, mounting, sliding, Ultrasonic Depth
Sensor (mounting plate)
8000-0307
1 as
needed
Bracket, adapter, sliding (for mounting
Ultrasonic Depth Sensor to existing I25-0001
mounting plate)
8000-0299
1 as
needed
Bracket, mounting, slide, Surface Combo
Sensor (mounting plate)
8000-0307
1 as
needed
Adapter, silt mount for Peak Combo Sensor
8000-0271
1
Stainless steel ring (sized for pipe)
I25-0081 to 0094
See Appendix B
Up to 2
(1 per
monitoring
point)
Peak Combo Sensor
– upward ultrasonic depth
sensor, pressure depth sensor, & peak velocity
sensor w/ M3 x 6mm stainless steel, flathead
screws
8K-CS4-xx-35/1H
(35-ft./10.6-m or
100-ft./30.5-m
cable)
2