6-60 ADS TRITON+ Manual

Trigger Enter the sampling trigger threshold corresponding to
the selected Type for which you want the sampler activities to
initiate. For example, if Depth is the selected Type, enter the
corresponding threshold value in inches (or millimeters) at
which you want the monitor to pulse the sampler.

Samples per wakeup Select and enter or use the up/down
arrows to indicate the total, consecutive number of times you
want the monitor to pulse the sampler within a single interval
each time the trigger condition is met.

Pulse Length Enter the duration of the pulse you want to
send to the sampler once sampling activities begin.

Data Optimization

Velocity Scrubbing Select this checkbox to ensure the
monitor confirms questionable or erroneous velocity readings
based on the historical relationship between the ultrasonic
depth and velocity data for the location.

Automatic Pressure Calibration Select this checkbox to
ensure the monitor automatically calibrates questionable or
erroneous pressure depth data to read consistently with the
ultrasonic depth data. The monitor will maintain a running
average of the difference between the pressure depth and the
ultrasonic depth data throughout the day. At midnight each
day, the monitor will apply a new offset based on the most
recent difference in the running average.

Combo Sensor to Use

Depth Select the combo sensor containing the depth sensor
you want to use for processes involving MLI and to generate
UNIDEPTH.

Velocity Select the combo sensor containing the velocity
sensor you want to use for processes involving MLI and to
generate RAWVEL.