30 ads triton+ manual – ADS Environmental Services ADS TRITON+ QR 775027 A3 User Manual
Page 351

10-30 ADS TRITON+ Manual
also can get trapped between the two parts while tightening
the bolts on the monitor top, preventing an effective
air/watertight seal and potentially damaging the battery
cable and/or the gasket.
L
E
N
N
A
H
C
2
SENS
CPU
E
T
N
A
A
N
N
SENSORS
L
E
N
N
A
H
C
1
WAKE
When securing top to canister,
always align COMM+EXT PWR connector
with backside of canister
and molded mounting flange.
+ EX T
R
w w w.adsenv.com
C
O
MM
PW
R
TM
STAT US
CONTAINS CELL XMTR
FCC ID: R17HE910
Ex ia IIB T3(152°C) Ga
Sira 09ATEX2027X
II 1 G
0518
MODEL: 8000 - FHK/FST-IM
Use only battery pack 8000-0043
IECEx SIR09.0020X
Ta = -20°C to +60°C
Ex ia IIB T3(152°C) Ga
Rev
DATE
MODEL: 8000 - FHK/FST-IM
Utilisez uniquement la batterie 8000-0043
Ta = -20°C to +60°C
CSA 2013 2671180
Ex ia IIB T3 (152°C)
S/N
See CONTROL DWG 8000BK0009
Voir SCHEMA DE CONTROLE
Use only battery pack 8000-0043
SIR 006
Returning the monitor top to the proper orientation with the canister
18. Finger-tighten the top bolts to make sure the top and gasket are
seated properly. Then, tighten the bolts about halfway to full
torque value by tightening the opposite bolts. Finally, tighten
the bolts to approximately 30 inch-pounds (2.50 foot-pounds/
3.39 Nm) to fully secure the top to the canister. If the monitor
will not seal, loosen the bolts and check for a trapped wire or
debris on either the gasket or the lip. You can increase the
torque value on the bolts incrementally to assist in sealing.
However, tighten the bolts evenly to prevent distorting the
gasket and do not exceed 45-inch pounds (5.0843Nm).