10-30 ADS TRITON+ Manual

also can get trapped between the two parts while tightening
the bolts on the monitor top, preventing an effective
air/watertight seal and potentially damaging the battery
cable and/or the gasket.

L

E

N

N

A

H

C

2

SENS

CPU

E

T

N

A

A

N

N

SENSORS

L

E

N

N

A

H

C

1

WAKE

When securing top to canister,

always align COMM+EXT PWR connector

with backside of canister

and molded mounting flange.

+ EX T

R

w w w.adsenv.com

C

O

MM

PW

R

TM

STAT US

CONTAINS CELL XMTR

FCC ID: R17HE910

Ex ia IIB T3(152°C) Ga

Sira 09ATEX2027X

II 1 G

0518

MODEL: 8000 - FHK/FST-IM

Use only battery pack 8000-0043

IECEx SIR09.0020X

Ta = -20°C to +60°C

Ex ia IIB T3(152°C) Ga

Rev

DATE

MODEL: 8000 - FHK/FST-IM

Utilisez uniquement la batterie 8000-0043

Ta = -20°C to +60°C

CSA 2013 2671180
Ex ia IIB T3 (152°C)

S/N

See CONTROL DWG 8000BK0009

Voir SCHEMA DE CONTROLE

Use only battery pack 8000-0043

SIR 006

Returning the monitor top to the proper orientation with the canister

18. Finger-tighten the top bolts to make sure the top and gasket are

seated properly. Then, tighten the bolts about halfway to full
torque value by tightening the opposite bolts. Finally, tighten
the bolts to approximately 30 inch-pounds (2.50 foot-pounds/
3.39 Nm
) to fully secure the top to the canister. If the monitor
will not seal, loosen the bolts and check for a trapped wire or
debris on either the gasket or the lip. You can increase the
torque value on the bolts incrementally to assist in sealing.
However, tighten the bolts evenly to prevent distorting the
gasket and do not exceed 45-inch pounds (5.0843Nm).