beautypg.com

ADS Environmental Services ADS TRITON+ QR 775027 A3 User Manual

Page 365

background image

10-44 ADS TRITON+ Manual

Problem

Range from the ultrasonic depth subsystem is too short
(but not zero).

Possible

Causes

Pipe height may be incorrect.

Electronic offset may be incorrect.

Sensor may be dirty.

Sensor may be faulty.

Possible

Solutions

Verify the pipe height.

Verify electronic offset and adjust if necessary.

Clean the sensor.

Replace the sensor.

Contact your regional ADS representative.

Problem

Raw ultrasonic depth data shows depths greater than
the pipe diameter.

Possible

Causes

Physical offset may be incorrect.

Pipe height may be incorrect.

Electronic offset may be incorrect.

Pipe may be surcharged.

Sensor may be dirty.

Sensor may be faulty.

Possible

Solutions

Verify the physical offset.

Verify the pipe height.

Verify electronic offset and adjust if necessary.

Clean the sensor.

Replace the sensor.

Contact your regional ADS representative.