beautypg.com

ADS Environmental Services ADS TRITON+ QR 775027 A3 User Manual

Page 21

background image

1-14 ADS TRITON+ Manual

The equipment is only certified for use in ambient temperatures
in the range of -20

o

C to +60

o

C and should not be used outside

this range.

The certificate number has an ‘X’ suffix, which indicates that
special conditions apply to installation and use. Those
installing or inspecting this equipment must have access to the
contents of the certificate.

Installation shall be carried out in accordance with the
applicable code of practice by suitably-trained personnel.

Repair of this equipment shall be carried out in accordance
with the applicable code of practice.

If the equipment is likely to come into contact with aggressive
substances, then it is the responsibility of the user to take
suitable precautions that prevent it from being adversely
affected, thus ensuring that the type of protection is not
compromised.

 Aggressive substances such as acidic liquids or gases that

may attack metals, or solvents that may affect polymeric
materials

 Suitable precautions such as regular checks as part of

routine inspections or establishing from the material’s data
sheet that it is resistant to specific chemicals

There are no special inspections or maintenance conditions
other than a periodic check.

TRITON+ monitors delivered outside the U.S. must bear the
following label to substantiate conformance to ATEX and CSA
standards as certified through Sira Certification Services: