3-2 ADS TRITON+ Manual
Install the Sensors in the Pipe This process primarily
includes assembling the ring (for standard installations) or
preparing the bands (for special installations) to which the
sensors attach, mounting the sensors to the ring or bands,
securing the sensor cables to the ring or band, and installing the
ring or bands in the pipe.
Secure and Connect the Cables This procedure involves
securing the sensor cables from the ring or band to the monitor
location in the manhole and connecting the sensors to the
TRITON+ monitor. It also includes general instructions for
connecting a third-party water quality sampler to the monitor.
ULTRASONIC DEPTH SENSOR
PEAK COMBO SENSOR
TRITON+ MONITOR
FLOW
SURFACE COMBO SENSOR
OR
INSTALLATION
RING
TM
Typical TRITON+ flow monitor and sensor installation
This chapter contains instructions for properly installing the sensors
in sanitary, storm, and combined sewer lines and manholes.
Note: Manhole and sewer system work involves confined
space entry and is inherently dangerous. Therefore,
installers and technicians must comply with all federal,
state, and municipal regulations concerning confined space
entry. ADS is not responsible for any injuries, damages,