Configuration and Activation 6-59

outside a designated tolerance. The monitor calculates the
differences using a running average to minimize the possibility of
anomalies that may trigger false alarms. The monitor also will log
an event when the difference in readings falls back below the
designated tolerance.

Enable Depth Select this checkbox to ensure the monitor
logs a CROSS_DEPTH event when the difference between at
least two of the depth readings at the monitoring point exceeds
the corresponding tolerance.

Tolerance Enter the difference in depth measurements
beyond which you want the monitor to log a cross check event.

Enable Velocity Select this checkbox to ensure the monitor
logs a CROSS_VELOCITY event when the difference between
at least two of the velocity readings at the monitoring point
exceeds the corresponding tolerance.

Tolerance Enter the difference in velocity measurements
beyond which you want the monitor to log a cross check event.

Sampling

Edit the parameters in this section in order to manage water quality
sampling activities associated with a TRITON+.

Note: Water quality sampling cannot be performed on
externally powered TRITON+ monitors.

Type Select the triggering method you want to use to initiate
sampling operations from Depth, Flow Rate, or Flow
Total
. Trigger values are based on readings returned from the
selected sensors in the Combo Sensor to Use section of the
MLI device. Choose Depth to initiate sampling based on
unidepth readings from the selected depth combo sensor. Flow
Rate
and Flow Total are instantaneous calculations based on
the selected depth and velocity sensors in the Combo Sensor
to Use
.