Rockwell Automation 2090 Ultra3000 Servo Drives Integration Manual User Manual
Page 118
Publication 2098-IN005C-EN-P — March 2008
118
Interconnect Diagrams
This is the power wiring diagram with 24V dc control string for
2098-DSD-HVxxx-xx and 2098-DSD-HVxxxX-xx Ultra3000 drives. For
the control string diagram with 120V ac input refer to the figure on
page 130.
Typical Power Wiring of Ultra3000 (460V) System
TB1
DC+
DC-
W
V
U
L2
L3
CN1
43
44
L1
TB2
1
2
3
L3
L2
L1
L1 AUX
L2/N AUX
43
44
CN1
43
44
2098-DSD-HVxxx-xx and
2098-DSD-HVxxxX-xx
Ultra3000
Digital Servo Drives
Note 14
AC Input Power
Connections
Motor Power
Connections
Three-phase
AC Line Filter
Three-phase Input
230-480V ac RMS
Fused Disconnect
or Circuit Breaker *
Note 1
Isolation
Transformer *
Note 2
Chassis
Bonded Cabinet
Ground Bus *
Terminal Blocks *
Note 3
To additional
Ultra3000 drive
Three-phase
Motor Power
Connections
Cable Shield
Clamp
Note 9
STOP *
START *
CR1 *
CR1 *
CR1 *
M1 *
Refer to Attention statement (Notes 10, 11)
N.O. Relay Output+
N.O. Relay Output-
Note 22
24V dc
Neutral
M1 *
External Passive
Shunt Connections
(refer to examples
beginning on page 119)
Input Fusing*
Three-phase AC Line
50/60 Hz
Note 6
* Indicates User-supplied Component