beautypg.com

Replacing snubber and sharing resistor – Rockwell Automation 7000 PowerFlex Medium Voltage AC Drive (B Frame) - ForGe Control User Manual

Page 72

background image

72

Rockwell Automation Publication 7000-UM202B-EN-P - June 2014

Chapter 3

Component Definition and Maintenance

Figure 61 - Replacing the SGCT (heat pipe model)

Replacing Snubber and Sharing Resistor

The snubber and sharing resistors are part of the resistor assembly located behind
the PowerCage.

1.

Remove the PowerCage as outlined in

Removing the PowerCage on

page 99

.

Note the connection of the leads for correct replacement.

2.

Detach the leads located on the bottom of the resistor assembly.

Clamp Head

DO NOT ADJUST
outside nut

Inside nut used for loosening
and applying load to assembly

Disc Springs

SGCT
Captive
Screws