EtherNet/IP Objects
Instance Attributes
Attribute ID
Access Rule
Name
Data Type
Description
6
Get
DPI Offline Read Full
STRUCT of:
BOOL[32]
CONTAINER
CONTAINER
CONTAINER
STRING[16]
STRING[4]
UINT
UINT
UINT
UINT
UINT
UINT
UINT
USINT
USINT
UINT
UINT
CONTAINER
UINT
UNIT
UNIT
INT
Descriptor
Offline Minimum value
Offline Maximum value
Offline Default value
Parameter name
Offline parameter units
Online minimum parameter instance
Online maximum parameter instance
Online default parameter instance
Multiplier parameter instance
Divisor parameter instance
Base parameter instance
Offset parameter instance
Formula number
Pad byte (always zero)
Help instance
Pad word (always a value of zero)
Parameter value
Multiplier
Divisor
Base
Offset
7
Get
DPI Online Read Full
STRUCT of:
BOOL[32]
CONTAINER
(1)
CONTAINER
CONTAINER
CONTAINER
UINT
UINT
STRING[4]
UINT
UINT
UINT
INT
USINT[3]
USINT
STRING[16]
Descriptor (see
Parameter value
Minimum value
Maximum value
Default value
Next parameter
Previous parameter
Units (for example, Amps, Hz)
Multiplier
(2)
Divisor
(2)
Base
(2)
Offset
(2)
Link (source of the value) (0 = no link)
Always zero (0)
Parameter name
8
Get
DPI Descriptor
BOOL[32]
Descriptor (see
9
Get/Set
DPI Parameter Value
Various
Name of the component with support for Unicode.
10
Get/Set
DPI RAM Parameter Value
Various
Parameter value in NVS.
(3)
14
Get
DPI Parameter Name
STRING[16]
Parameter name
18
Get
International DPI Offline Parameter Text
Struct of:
STRINGN
STRINGN
International parameter name
International offline units
19
Get
International DPI Online Parameter Text
Struct of:
STRINGN
STRINGN
International parameter name
International online units