Rockwell Automation 25-COMM-E2P PowerFlex 25-COMM-E2P Dual-Port EtherNet/IP Adapter User Manual
Page 119

Rockwell Automation Publication 520COM-UM003A-EN-E - June 2013
119
Troubleshooting
Chapter 8
12
Drv 2 Reference
The present value of the Reference being transmitted to drive 2 by this adapter.
13
Drv 2 Logic Sts
The present value of the Logic Status being received from drive 2 by this adapter.
14
Drv 2 Feedback
The present value of the Feedback being received from drive 2 by this adapter.
15
Drv 3 Logic Cmd
The present value of the Logic Command being transmitted to drive 3 by this adapter.
16
Drv 3 Reference
The present value of the Reference being transmitted to drive 3 by this adapter.
17
Drv 3 Logic Sts
The present value of the Logic Status being received from drive 3 by this adapter.
18
Drv 3 Feedback
The present value of the Feedback being received from drive 3 by this adapter.
19
Drv 4 Logic Cmd
The present value of the Logic Command being transmitted to drive 4 by this adapter.
20
Drv 4 Reference
The present value of the Reference being transmitted to drive 4 by this adapter.
21
Drv 4 Logic Sts
The present value of the Logic Status being received from drive 4 by this adapter.
22
Drv 4 Feedback
The present value of the Feedback being received from drive 4 by this adapter.
23
Input Size
Displays the size of the input image in bytes transferred from the network to the drive.
24
Output Size
Displays the size of the output image in bytes transferred from the drive to the network.
25...32 Reserved
–
33
Opt Comm Errs
A count of the number of adapter to drive communication errors
34
35
36
37
38
39
HW Addr 1
HW Addr 2
HW Addr 3
HW Addr 4
HW Addr 5
HW Addr 6
Decimal value of each octet in the adapter’s Ethernet hardware address.
40
41
42
43
IP Addr Act 1
IP Addr Act 2
IP Addr Act 3
IP Addr Act 4
Value of each octet in the adapter’s present IP address. A value of “0” appears if the
adapter does not currently have an IP address.
44
45
46
47
Subnet Act 1
Subnet Act 2
Subnet Act 3
Subnet Act 4
Value of each octet in the adapter’s present subnet mask. A value of “0” appears if the
adapter does not currently have a subnet mask.
48
49
50
51
Gateway Act 1
Gateway Act 2
Gateway Act 3
Gateway Act 4
Value of each octet in the adapter’s present gateway address. A value of “0” appears if the
adapter does not currently have a gateway address.
52
Net Rx Overruns
A count of the number of receive overrun errors reported by the adapter.
Dual-port EtherNet/IP Adapter Diagnostic Items in Multi-Drive Mode
No.
Name
Description
255.255.255.255.255.255
[HW Addr 1]
[HW Addr 2]
[HW Addr 3]
[HW Addr 4]
[HW Addr 5]
[HW Addr 6]
255.255.255.255
[IP Addr Act 1]
[IP Addr Act 2]
[IP Addr Act 3]
[IP Addr Act 4]
255.255.255.255
[Subnet Act 1]
[Subnet Act 2]
[Subnet Act 3]
[Subnet Act 4]
255.255.255.255
[Gateway Act 1]
[Gateway Act 2]
[Gateway Act 3]
[Gateway Act 4]