Mechanical installation – Lenze 8400 User Manual
Page 91

Mechanical installation
Standard devices in a power range of 0.25 ... 3 kW
Assembly without filter in ”standard” technique
5
91
EDS84ASC552 EN 9.1
StateLine, HighLine
8400GG105k
Fig. 5-2
Dimensions for mounting
d
1
d
2
d
3
c
c
1
c
2
i
j
11
j
21
[kW]
[mm]
[kg]
E84AVxxE2512xXx
0.25
9
5
180
70
35
35
0
> 95
> 95
1.3
E84AVxxE3712xXx
0.37
E84AVxxE3714xXx
0.37
9
5
230
70
35
35
0
> 95
> 95
1.8
E84AVxxE551xxXx
0.55
E84AVxxE751xxXx
0.75
E84AVxxE112xxXx
1.1
8
10
285
70
35
35
0
> 95
> 95
2.1
E84AVxxE152xxXx
1.5
E84AVxxE222xxXx
2.2
E84AVxxE3024xXS
3.0
E84AVxxE2512xBx
0.25
9
5
180
70
35
35
0
> 95
> 95
1.4
E84AVxxE3712xBx
0.37
E84AVxxE3714xBx
0.37
9
5
230
70
35
35
0
> 95
> 95
1.9
E84AVxxE551xxBx
0.55
E84AVxxE751xxBx
0.75
E84AVxxE112xxBx
1.1
8
10
285
70
35
35
0
> 95
> 95
2.2
E84AVxxE152xxBx
1.5
E84AVxxE222xxBx
2.2
E84AVxxE3024xBS
3.0