Diagnostics
Display of operating data, diagnostics
Drive diagnostics via keypad
9
269
EDS84ASC552 EN 9.1
Parameter
Display
C00183
Device state
C00168
Error number
C00051
Actual speed value
C00052
Motor voltage
C00054
Motor current
C00057/1
Maximum torque
C00057/2
Torque at maximum current
C00059
Motor - number of pole pairs
C00061
Heatsink temperature
C00062
Temp. inside the controller
C00063
Motor temperature
C00064
Device utilisation (I x t) over the last 180 seconds
C00065
Ext. 24-V voltage
C00066
Thermal motor load (I
2
xt)
C00178
Time the controller was enabled (elapsed-time meter)
C00179
Time the mains was switched on (power-on time meter)
Identification data
The parameters listed in the following table which are classified in the »Engineer«
parameter list and the keypad in the category IdentificationController serve to display
the identification data of the controller.
Parameter
Display
C00099
Firmware version
C00200
Firmware product type
C00201
Firmware compilation date
C00203/1 ... 9
HW product types
C00204/1 ... 9
HW serial numbers
C00205/1 ... 6
HW descriptions
C00206/1 ... 6
HW manufacturing data
C00208/1 ... 6
HW manufacturer
C00209/1 ... 6
HW countries of origin
C00210/1 ... 6
HW version