Mechanical installation
Standard devices in a power range of 0.25 ... 3 kW
Mounting in ”cold plate” technique
5
104
EDS84ASC552 EN 9.1
Ambient conditions
ƒ
The rated data and the derating factors at increased temperature also apply to the
ambient temperature of the drive controllers.
ƒ
Temperature at the cooling plate of the drive controller: max. 75 °C.
Note!
Apply standard heat-conducting paste or heat-conducting foil onto cooler and
cooling plate before you bolt the controller onto the cooler.
StateLine, HighLine
8400GG105c
Fig. 5-11
Device dimensions
h
b
t
h
1
h
2
b
1
t
1
g
1
g
2
[kW]
[mm]
E84AVxxC2512xX0
0.25
165
102
185
186
226
70
172
6
5
E84AVxxC3712xX0
0.37
E84AVxxC3714xX0
0.37
215
102
163
236
276
70
150
6
5
E84AVxxC551xxX0
0.55
E84AVxxC751xxX0
0.75
E84AVxxC112xxX0
1.1
270
137
163
295
335
70
150
6
5
E84AVxxC152xxX0
1.5
E84AVxxC222xxX0
2.2
E84AVxxC2512xB0
0.25
165
102
205
186
226
70
192
6
5
E84AVxxC3712xB0
0.37
E84AVxxC3714xB0
0.37
215
102
183
236
276
70
170
6
5
E84AVxxC551xxB0
0.55
E84AVxxC751xxB0
0.75
E84AVxxC112xxB0
1.1
270
137
183
295
335
70
170
6
5
E84AVxxC152xxB0
1.5
E84AVxxC222xxB0
2.2