Safety engineering
Electrical installation
10
284
EDS84ASC552 EN 9.1
HW revision: Up to 1B
X80
Labelling
Description
Electrical data
SIA
SI
B
GI
24O
DO1
GO
SIA
Safe input, channel A
SIA: I
typ
= 100 mA
GI
GND potential for SIA/SIB
LOW: -3 ... 5 V,
HIGH: 15 ... 30 V
SIB
Safe input, channel B
SIB: I
typ
= 28 mA
Supply through safely
separated power supply unit
(SELV/PELV)
GO
GND potential feedback
24 V, max. 0.7 A
short-circuit-proof
LOW-active
Supply through safely
separated power supply unit
(SELV/PELV)
24O
24 V voltage supply feedback
E84ABSB003
DO1
Non-safe signalling output: ”Safe pulse
inhibit”
HW revision: From 2A
X80
Labelling
Description
Electrical data
SIA
SI
B
GI
24O
DO1
GO
SIA
Safe input, channel A
SIA, SIB: I
typ
= 12 mA
LOW: -3 ... 5 V,
HIGH: 15 ... 30 V
Supply through safely
separated power supply unit
(SELV/PELV)
GI
GND potential for SIA/SIB
SIB
Safe input, channel B
GO
GND potential feedback
24 V, max. 0.7 A
short-circuit-proof
LOW-active
Supply through safely
separated power supply unit
(SELV/PELV)
24O
24 V voltage supply feedback
DO1
Non-safe signalling output: ”Safe pulse
inhibit”
E84ABSB003
Terminal data
Conductor cross-section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb-in]
Rigid
0.14 ... 1.5
26 ... 16
Spring terminal
With wire end
ferrule
0.25 ... 0.5
24 ... 20