Technical data, Current characteristics – Lenze 8400 User Manual
Page 70

Technical data
Current characteristics
4
70
EDS84ASC552 EN 9.1
Maximum output currents [A]
1)
at a variable switching frequency
U
Lr
= 230V
Type
I
aM0v
I
aMv
E84AVxxx2512
3.4
3.4
E84AVxxx3712
4.8
4.8
E84AVxxx5512
6.0
6.0
E84AVxxx7512
8.0
8.0
E84AVxxx1122
8.3
11.0
E84AVxxx1522
10.5
14.0
E84AVxxx2222
14.3
19.0
Maximum output currents [A]
1)
at a variable switching frequency
U
Lr
= 400V/U
Lr
= 500V
Type
I
aM0v
I
aMv
E84AVxxx3714
2.6
2.6
E84AVxxx5514
3.6
3.6
E84AVxxx7514
4.8
4.8
E84AVxxx1124
4.8
6.4
E84AVxxx1524
5.9
7.8
E84AVxxx2224
8.4
11.2
E84AVxxx3024xxS
11.0
14.6
E84AVxxx3024xx0
11.0
14.6
E84AVxxx4024
14.3
19.0
E84AVxxx5524
19.5
26.0
E84AVxxx7524
24.8
33.0
E84AVxxx1134
35.3
47.0
E84AVxxx1534
48.0
64.0
E84AVxxx1834
58.5
78.0
E84AVxxx2234
70.5
89.3
E84AVxxx3034
88.5
112.1
E84AVxxx3734
108.0
136.8
E84AVxxx4534
133.5
169.1
1)
The shown values apply to the operation with ambient temperatures of up to +45°C for 2/4kHz and up to +40°C for
8/16kHz. For ambient temperatures between +40/45°C and +55°C, a derating from 2.5 %/K to the given values must