Safety instructions

General safety and application instructions for Lenze motors

2

17

EDS84ASC552 EN 9.1

Commissioning and operation
Before commissioning after longer storage periods, measure insulation resistance. In case

of values  1 k per volt of rated voltage, dry winding.
For trial run without output elements, lock the featherkey. Do not deactivate the

protective devices, not even in a trial run.
Check the correct operation of the brake before commissioning lowvoltage machines with

brakes.
Integrated thermal detectors do not provide full protection for the machine. If necessary,

limit the maximum current. Parameterise the controller so that the motor will be switched

off with I > I

rated

after a few seconds of operation, especially at the risk of blocking.

Vibrational severities v

eff

 3.5 mm/s (P

rated

 15 kW) or 4.5 mm/s (P

rated

> 15 kW) are

acceptable if the clutch is activated.
If deviations from normal operation occur, e.g. increased temperatures, noises, vibrations,

find the cause and, if required, contact the manufacturer. In case of doubt, switch off the

lowvoltage machine.
If the machine is exposed to dirt, clean the air paths regularly.
Shaft sealing rings and roller bearings have a limited service life.
Regrease bearings with relubricating devices while the lowvoltage machine is running.

Only use the grease recommended by the manufacturer. If the grease drain holes are

sealed with a plug, (IP54 drive end; IP23 drive and nondrive end), remove plug before

commissioning. Seal bore holes with grease. Replace prelubricated bearings (2Z bearing)

after approx. 10,000 h 20,000 h, at the latest however after 3 4 years.
The productspecific safety and application notes given in these instructions must be

observed!!