Electrical installation, Example circuit – Lenze 8400 User Manual
Page 235
Electrical installation
HighLine C control terminals
Digital inputs and outputs
6
235
EDS84ASC552 EN 9.1
Example circuit
Note!
For stable digital output states, in particular during the starting phase of the
controller, you must use an external 24V supply for the digital outputs.
Note!
Digital inputs and digital outputs have separated reference potentials (GI and
GO). If you interconnect inputs and outputs, the reference potentials are
connected as well by an external bridge.
DC 24 V
(+19.2...+28.8 V)
S1
24 V int.
50
mA
24E
DI1
DI2
DI3
DI4
RFR
2.7k
2.7k
3.3k
3.3k
3.3k
X5
GND-I
DI5
DI6
DI7
GI
24I
1.6k
1.6k
3.3k
E84AVHC...
24O
DC 24 V
(+19.2...+28.8 V)
X4
DO1
DO2
DO3
GO
GND-O
E84AVHC...
8400HLC045
8400HLC045
24 V int.
50
mA
24E
DI1
DI2
DI3
DI4
RFR
DC 24 V
(+19.2...+28.8 V)
S1
3.3k
2.7k
2.7k
3.3k
X5
GND-I
DI5
DI6
DI7
GI
24I
3.3k
1.6k
1.6k
3.3k
"
E84AVHC...
8400xLC022
Fig. 6-44
Wiring examples of the digital inputs and outputs
Wiring with one (or several) digital input (here: DI1), e.g. a PLC; optional: external
24 V supply
Digital control (relay, valve, ...) with external 24 V supply
Connection of an HTL incremental encoder with a maximum input frequency of
200 kHz
DI1
track A
DI2
track B
X4
Terminal for the digital outputs
X5
Terminal for the digital inputs
GI
GND-I
Ground reference potential for the digital inputs
GO
GND-O
Ground reference potential for the digital outputs