3 connection of relay output, Connection of relay output, Electrical installation – Lenze 8400 User Manual
Page 219
Electrical installation
Common control terminals
Connection of relay output
6
219
EDS84ASC552 EN 9.1
6.6.3
Connection of relay output
X101
NC
COM
X101
NO
8400GG009
8400GG010
Fig. 6-32
Wiring of the relay outputs
Labelling
Description
COM
Central contact of relay
AC 250 V, 3 A
DC 24V, 2A
DC 240 V, 0.16 A
According to UL508C:
– 3 A, 250 V AC (general purpose)
– 2 A, 24 V DC (resistive)
– 0.16 A, 240 V DC (general purpose)
NC
Relay output NC (normally closed)
Position is displayed via TRIP software message
(Lenze setting)
NO
Relay output NO (normally open)
Terminal data
Conductor cross-section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb-in]
flexible
0.2 ... 1.5
24 ... 16
-
-
3.5 x 0.6
with wire end ferrule