7 highline c control terminals, 1 external supply voltage 24 v, External supply voltage 24 v – Lenze 8400 User Manual
Page 80: Technical data

Technical data
HighLine C control terminals
External supply voltage 24 V
4
80
EDS84ASC552 EN 9.1
4.7
HighLine C control terminals
4.7.1
External supply voltage 24 V
Labelling
Feature
Rated value
X5/24E
Connection for external 24 V supply
voltage by a safely separated
power supply unit (required for
mains-independent supply of the
control electronics and the
communication module)
24 V in accordance with IEC 61131-2
19.2 ... 28.8 V
Residual ripple max. 5 %
SELV/PELV
Suppression of voltage pulses
Suppressor diode 36 V, bidirectional
Polarity reversal protection
When polarity is reversed: no function and no
destruction
Current consumption
Approx. 0.6 A during operation
Max. 1.5 A starting current for 100 ms
Capacity to be charged
1000 F
X5/GI
GND, reference potential for digital signals
Labelling
Feature
Rated value
X4/24O
Connection for external 24 V supply
voltage by a safely separated
Power supply unit (required for the
supply of the digital outputs)
24 V in accordance with IEC 61131-2
19.2 ... 28.8 V
Residual ripple max. 5 %
SELV/PELV
Suppression of voltage pulses
Suppressor diode 36 V, bidirectional
Polarity reversal protection
When polarity is reversed: no function and no
destruction
Current consumption
Approx. 0.15 A if all digital outputsare loaded with rated
current
X4/GO
GND, reference potential for digital signals
Labelling
Feature
Rated value
X5/24I
24 V voltage output
for connection of the digital inputs via
potential-free contacts
External supply at 24E: voltage drop < 2.5 V
Internal supply: DC 18 ... 28 V
Max. output current
50 mA
Electric strength of external voltage
+30 V
Excess current release
Automatically resettable
X5/GI
GND, reference potential for digital signals